APPLICATIONS
Power solutions for
real-world Applications
Every site has unique challenges. We design and deliver the right mix of diesel, hybrid and battery power solutions to keep your operations running.
Construction & Infrastructure
Temporary power for construction sites of all sizes – from housing projects and commercial buildings to civil works and infrastructure. Changing loads, starting peaks and site constraints make the right power solution critical for safety, productivity and cost control.
- Grid connection or off-grid supply?
- Peak load vs average load (cranes, pumps, hoists)
- Runtime profile: daytime only vs 24/7 operations
- Noise and location constraints (urban / residential)
- Mobility and phase changes across the project
- Fuel autonomy and service access on site
- Oversizing the system for short peak events
- Under sizing and tripping on starting peaks
- Inefficient low-load operation and high fuel cost
- Noise complaints or site restrictions
- Insufficient fuel or poor maintenance planning
- Limited monitoring and slow fault response
DECISION SUPPORT
- Analyse your load profile and site requirements
- Identify true continuous load vs short peak events
- Recommend the right mix of diesel, battery and controls
- Translate constraints into a practical and compliant solution
RISK MITIGATION
- Right-size the system to avoid oversizing and inefficiency
- Protect against peak events with battery support
- Reduce noise and emissions where it matters
- Ensure uptime with monitoring and fast technical response
NORDGEN FIT (INDICATIVE)
- Diesel gensets (NG60 - NG250) for base / continuous load
- BESS (NG100-H, NG200-H and larger) for peak shaving and quiet periods
- Hybrid solutions combining diesel + battery for maximum efficiency and flexibility
- Engineered for mobility, rental use and demanding site conditions
Events & Urban Installations
Low-noise, compact temporary power for events, festivals, public installations and urban sites.
- Noise limits and quiet-hour requirements
- Short setup and removal window
- Compact footprint and public access constraints
- Variable load during build-up, live event and teardown
- Need for fuel autonomy and clean cable routing
- Noise complaints or permit issues
- Undersized system during live event peaks
- Poor access or unsafe public interface
- Overrunning setup or teardown schedule
- Fuel logistics disrupting event operations
DECISION SUPPORT
- Map event phases and expected load changes
- Define quiet-period battery or hybrid logic
- Keep layout compact, safe and serviceable
- Support fast deployment and removal
RISK MITIGATION
- Noise complaints or permit issues
- Undersized system during live event peaks
- Poor access or unsafe public interface
NORDGEN FIT (INDICATIVE)
- Low-noise diesel gensets for main supply
- BESS for quiet periods and sensitive areas
- Hybrid systems for variable event load profiles
Industrial Temporary Power
Temporary power for shutdowns, maintenance windows, contingency support and demanding industrial loads.
- Continuity risk and allowed downtime
- Prime-duty runtime and redundancy needs
- Integration with site distribution and protection
- Fuel autonomy over long operating windows
- Service access during live operations
- Production loss from power interruption
- Wrong redundancy level for critical loads
- Poor interface with site electrical systems
- Insufficient runtime or refuelling plan
- Slow response during shutdown windows
DECISION SUPPORT
- Assess critical and non-critical loads
- Define redundancy and runtime requirements
- Coordinate practical connection logic
- Plan service access and support response
RISK MITIGATION
- Production loss from power interruption
- Wrong redundancy level for critical loads
- Poor interface with site electrical systems
NORDGEN FIT (INDICATIVE)
- >
- NG150-NG350 diesel gensets for heavy loads
- Parallel or backup configurations where needed
- BESS support for transitions or lower loads
Utilities & Temporary Grid Support
Temporary supply for outages, bypass power, grid maintenance, emergency support and temporary infrastructure.
- Planned bypass or emergency response
- Connection, protection and switching logic
- Runtime and fuel planning requirements
- Deployment speed and site access
- Operational monitoring and response level
- Extended outage or service disruption
- Incorrect protection or connection setup
- Delayed mobilization during urgent work
- Insufficient fuel autonomy
- Regulatory or public-impact issues
DECISION SUPPORT
- Translate outage needs into deployable package
- Support connection and runtime planning
- Recommend monitoring and response setup
- Specify robust, transportable configurations
RISK MITIGATION
- Extended outage or service disruption
- Incorrect protection or connection setup
- Delayed mobilisation during urgent work
NORDGEN FIT (INDICATIVE)
- NG200-NG350 diesel systems for temporary supply
- BESS for support and transition loads
- Hybrid where runtime optimisation matters
Peak Shaving & Load Support
Battery and hybrid support for short peak events, grid-limited sites and temporary load smoothing.
- Peak event duration and frequency
- Base load versus peak demand
- Available grid connection capacity
- Battery capacity and discharge requirements
- Generator oversizing risk
- Oversized diesel system for rare peaks
- Insufficient battery capacity for peak events
- Poor integration with generator or grid
- Battery underutilization due to wrong sizing
- Unexpected operating cost or complexity
DECISION SUPPORT
- Separate base load from peak events
- Size BESS around duration, not just power
- Define genset/BESS operating logic
- Reduce oversizing and avoidable runtime
RISK MITIGATION
- Oversized diesel system for rare peaks
- Insufficient battery capacity for peak events
- Poor integration with generator or grid
NORDGEN FIT (INDICATIVE)
- BESS50-BESS200 for peak support
- NG100-H/NG200-H hybrid packages
- Genset + BESS for load smoothing
Rental Fleet & Standard Packages
Repeatable rental-grade configurations focused on fleet consistency, serviceability and deployment speed.
- Standard KVA rungs and fleet coverage
- Common components and controller strategy
- Service access and maintenance intervals
- Transport, lifting and handling requirements
- Lifecycle cost and resale logic
- Too many one-off configurations
- Higher maintenance complexity
- Poor operator familiarity
- Spare-parts fragmentation
- Unclear total cost of ownership
DECISION SUPPORT
- Define standard package logic
- Reduce unnecessary configuration variation
- Use practical component choices
- Support serviceable and repeatable feet deployment
RISK MITIGATION
- Too many one-off configurations
- Higher maintenance complexity
- Poor operator familiarity
NORDGEN FIT (INDICATIVE)
- NG60 / NG100 / NG150 rental-grade gensets
- NG100-H for variable-load fleet use
- Standard canopy, control and service options
contact us
talk to
an expert
Fill in the form with your information if you want one of our generator sets or if you have any questions. We will prepare a quotation for you based on your requirements.
Customer service team Email
Technical information
Project description / Other details
What technical needs should the generator you need satisfy? Power, mode, frequency / voltage, high / low temperatures, reduced space, soundproofing, etc.
Project description / Other details
Attached documentation
(maximum file size 1Mb, PDF format)
I have read and accept the privacy policy of NORDGEN POWER, as well as the conditions related to the treatment and use of personal information.